105
Update
Chapter 4
Defining Output Format
4.6.1 EDIT A CONCATENATION OF BARCODES
1) Read the label above to start editing a concatenation of barcodes.
2) Code Type setting – read the “
Hexadecimal Value” label on page 138 for Code Type of
the (first) barcode. For example, read “4” and “1” for Code 39.
Code Type
Symbology Code Type Symbology
41 (A) Code 39 4F (O) EAN-8 with Addon 5
42 (B) Italian Pharmacode 50 (P) EAN-13
43 (C) French Pharmacode) 51 (Q) EAN-13 with Addon 2
44 (D) Industrial 25 52 (R) EAN-13 with Addon 5
45 (E) Interleaved 25 53 (S) MSI
46 (F) Matrix 25 54 (T) Plessey
47 (G) Codabar (NW7) 55 (U) EAN-128
48 (H) Code 93 56 (V) UPC-A
49 (I) Code 128 57 (W) UPC-A with Addon 2
4A (J) UPC-E0 / UPC-E1 58 (X) UPC-A with Addon 5
4B (K) UPC-E with Addon 2
4C (L) UPC-E with Addon 5 5A (Z) Telepen
4D (M) EAN-8 5B ( [ ) RSS-14
4E (N) EAN-8 with Addon 2
3) Barcode Length setting – read the “
Decimal Value” label on page 137 for the 4-digit
length of the (first) barcode. For example, read “0065” for barcode length of 65
characters or read “0000” for any length.
Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix
(0x0d by default), length code, etc.
4) Matching Character setting – read the “Hexadecimal Value” label on page 138 for the
1
st
character that must be found matching in the (first) barcode. For example, read
“4” and “1” for matching character “A” as the first character in the barcode or read
“00” for any character.
5) Read twice the “F” label on page
138 (“FF”) to complete the setting of each barcode.
6) Read the “Validate” label to end the editing of the barcode set.
Edit Output Sequence