CipherLab 1660 Especificações Página 90

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 156
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 89
78
Enter Setup
1660 Barcode Scanner
User Guide
4.12.3 CODE LENGTH QUALIFICATION
Because of the weak structure of the symbology, it is possible to make a "short scan"
error. To prevent the "short scan" error, define the "Length Qualification" settings to
ensure that the correct barcode is read by qualifying the allowable code length.
If "Max/Min Length" is selected, the maximum length and the minimum length must
be specified. It only accepts those barcodes with lengths that fall between max/min
lengths specified.
If “Fixed Length” is selected, up to 2 fixed lengths can be specified.
1) Read the label to enable either Max. /Min. Length qualification or Fixed Length(s)
qualification.
2) Read the label for Max. Length or Fixed Length 1, and follow steps 3~4.
Repeat steps 2~4 for Min. Length or Fixed Length 2.
3) Read the “
Decimal Value” label on page 141 for the desired length.
4) Read the “Validate” label on the same page to complete this setting.
E
nable Fixed Length(s) …
*Enable Max./Min.
Length (0 ~ 127) …
Min. Length (*4)
Or Fixed Length 2
Max. Length (*127)
Or Fixed Length 1