Chapter 3 Changing Symbology Settings
3.5 CODE 39
By default, the scanner is set to read Code 39 barcodes.
Advanced settings are provided as shown below.
Code 39 Full ASCII
Decide whether to support Code 39 Full ASCII that includes all the alphanumeric and special
characters.
Transmit Start/Stop
Decide whether to include the start/stop characters in the data being transmitted.
Verify Check Digit
Decide whether to verify check digit when decoding Code 39 barcodes. If the check digit is
incorrect, the barcode will not be accepted.
Transmit Check Digit
The check digit will be included in the data being transmitted.
Cancel the check box if the check digit is not desired.